60%

5KV Insulation Resistance Meter Megohmmeter Resistance Tester Electrical Meters

Share On:

Original price was: $426.36.Current price is: $255.81.

Meta:
Meter Accuracy : Class 0.2
Other name : megohmmeter
function 3 : polarization index of DC voltage
Rated voltage : 100V、250V、500V、1000V、2500V、5000V
Data Storage : 500 groups
function 2 : absorption ratio
Application : Electrical Usage Meters
Features : Digital Meters, LCD Backlight, Smart Meter
UPC : Does not apply
MPN : Does not apply
Name : digital high-voltage insulation resistance meter
Brand : VLUUKE
gtin13 : Does not apply
function 1 : DC voltage, AC voltage
Used for : high voltage insulation resistance tester
Operating Frequency : 50/60 Hz

Remark: Common electrical unit conversion 1 T Ω( Tera ohm ) =1000G Ω =10 12 Ω 1 G Ω( Giga ohm ) =1000M Ω =10 9 Ω 1 M Ω( Mega ohm ) =1000K Ω =10 6 Ω 1. Voltage range & accuracy Measuring function Measuring range accuracy resolution DC voltage DC 0.0V~1000V ±5%rdg±3dgt 0.1 V AC voltage AC 0.0V~750V ±5%rdg±3dgt 0.1V 2. Current range & accuracy Measuring function Measuring range accuracy resolution DC current 1mA-6mA ± 5 %rdg± 2 dgt 0.01mA 100uA-1000uA ± 5 %rdg± 2 dgt 1uA 10uA-100uA ± 5 %rdg± 2 dgt 0.1uA 1uA-10uA ± 5 %rdg± 2 dgt 0.01uA 100nA-1000nA ± 5 %rdg± 2 dgt 1nA 10nA-100nA ± 1 0 %rdg±5dgt 0.1nA 1nA-10nA ±20 %rdg±5dgt 0.01nA 100pA-1000pA ±30 %rdg±5dgt 1pA 3. Capacitance range & accuracy Measuring function Measuring range accuracy resolution capacitance 10uf-50uf ±1 0 % fs. ±5dgt 0.01uf 1uf-10uf ±1 0 % fs. ±5dgt 0. 0 1uf 100nf-10 00 nf ±1 0 % fs. ±5dgt 1nf 10nf-100nf ±1 0 % fs. ±5dgt 0.1nf IV .Technical Specification s Function Insulation resistance test, voltage test, DC current test, capacitance test Basic condition 23 ℃± 5 ℃, below 75%rh KD2677 E Rated voltage 100V 、 250V 、 500V 、 1000V 、 2500V 、 5 000V Insulation resistance range 0.01M Ω~ 10T Ω resolution : 0.01M Ω KD2677 F Rated voltage 250V 、 500V 、 1000V 、 2500V 、 5000V 、 10KV Insulation resistance range 0.01M Ω~ 35T Ω resolution : 0.01M Ω KD2677 Rated voltage 500V 、 1000V 、 2500V 、 5000V 、 10KV 、 15KV Insulation resistance range 0.01M Ω~ 50T Ω resolution : 0.01M Ω Test Voltage(V) rated voltage× ( 1±10% ) DC Voltage Range 0 ~ 1000V R esolution : 0.1V AC Voltage Range 0 ~ 750V R esolution : 0.1V DC Current 0.1nA ~ 6mA R esolution : 0.1n A Capacitance 10nF ~ 50uF R esolution : 10nF Output short-circuit Current ≥ 6 mA @15KV Absorption Ratio and Polarization Index Measurement Have Filter test(FR) 10S 20S 30S 40S 50S Oblique wave test ( RAMP ) Target voltage %10 Step up to the final target voltage Power Supply 12 .6 V rechargeable battery Backlight Controllable gray screen backlight, suitable for use in dim places Dispaly mode 4-bit large LCD display, gray screen backlight LCD display size 108mm × 65mm Instrument size L/W/H : 240mm × 188mm × 85mm USB interface With USB interface, software monitoring, storage data can be uploaded to the computer, save and print Communication Line USB communication line 1PC Test Line High voltage rob red 3meter, high voltage test line black 1.5meter, green 1.5meter Data Storage 500 groups, “FULL” symbol indicates that storage is full Data Review Data review function: “MR” symbol display Overflow Display Exceed measurement range overflow function: “ > ” symbol display Alarm Function Alarm when the measured value larger or smaller than the alarm setting value Power Consumption Standby: 30mA Max(backlight off) , T urn on backlight: 42mA Max M easure : 2 00mA Max(backlight off) Instrument weight 27 5 0g(including battery) Battery voltage When the battery voltage is low, low battery symbol “ ”will display Automatic shut-down automatic shutdown after 15 minutes boot Insulation Resistance ≥50MΩ(between Measuring line and housing) Pressure Resistance AC3kV/50Hz 1min Working Temperature and Humidity - 10 ℃~ +50 ℃< 85%RH Storage Temperature and Humidity - 15 ℃~ +55 ℃< 90%RH Suitable for Safety Regulations IEC61010-1 、 IEC1010-2-31 、 IEC61557-1,5 、 IEC60529(IP54) 、 pollution grade 2 、 CAT Ⅲ 300V